Showing 1–16 of 27 results

C03-50A Open-Loop current sensor

Accuracy: 0.8%
Measuring Range: 50A
Output: 2.5±0.025V
Supply Voltage: 5V

The C03-50A series provides efficient and precise sensor solutions for AC, DC, and pulse currents in industrial, commercial and communications systems. It consists of three main components: an accurate low temperature drift linear hall sensor, a flux collector, and a current transformer. It offers markedly low resistance, reducing power loss and temperature drift to deliver exceptional performance.

C03-50AH Open-Loop current sensor

Accuracy: 0.8%
Measuring Range: 50A
Output: 2.5±0.025V
Supply Voltage: 5V

The C03-50A series provides efficient and precise sensor solutions for AC, DC, and pulse currents in industrial, commercial and communications systems. It consists of three main components: an accurate low temperature drift linear hall sensor, a flux collector, and a current transformer. It offers markedly low resistance, reducing power loss and temperature drift to deliver exceptional performance.

C03-50AH40 Open-Loop current sensor

Accuracy: 0.8%
Measuring Range: 50A
Output: 2.5±0.04V
Supply Voltage: 5V

The C03-50A series provides efficient and precise sensor solutions for AC, DC, and pulse currents in industrial, commercial and communications systems. It consists of three main components: an accurate low temperature drift linear hall sensor, a flux collector, and a current transformer. It offers markedly low resistance, reducing power loss and temperature drift to deliver exceptional performance.

C05 series Open-Loop current sensor

Accuracy: 0.8%
Measuring Range: 10A|16A|20A|32A|50A
Output: 2.5±0.8V@IPN
Supply Voltage: 5V

The C05 series current sensor provides efficient and precise sensor solutions for AC, DC and pulse currents in industrial, commercial and communications systems. It consists of three main components: an accurate low-temperature drift linear hall sensor, a flux collector and a current transformer. It offers markedly low resistance, reducing power loss and temperature drift to deliver exceptional performance.

C05-XXA33 series Open-Loop current sensor

Accuracy: 0.8%
Measuring Range: 10A|16A|20A|32A|50A|80A|100A|120A
Output: 1.65±0.46V@IPN
Supply Voltage: 3.3V

The C05 series current sensor provides efficient and precise sensor solutions for AC, DC and pulse currents in industrial, commercial and communications systems. It consists of three main components: an accurate low-temperature drift linear hall sensor, a flux collector and a current transformer. It offers markedly low resistance, reducing power loss and temperature drift to deliver exceptional performance.

C06 series Open-Loop current sensor

Accuracy: 0.8%
Measuring Range: 50A|100A|150A|200A|250A|300A|400A
Output: 2.5±2V@IPN
Supply Voltage: 5V

 The C06 series current sensor provides efficient and precise sensor solutions for AC, DC and pulse currents in industrial, commercial and communications systems. It consists of three main components: an accurate low-temperature drift linear hall sensor, a flux collector and a current transformer. It offers markedly low resistance, reducing power loss and temperature drift to deliver exceptional performance.

C06-XXA33 series Open-Loop current sensor

Accuracy: 0.8%
Measuring Range: 50A|100A|150A|200A|250A
Output: 1.65±1.32V@IPN
Supply Voltage: 3.3V

 The C06 series current sensor provides efficient and precise sensor solutions for AC, DC and pulse currents in industrial, commercial and communications systems. It consists of three main components: an accurate low-temperature drift linear hall sensor, a flux collector and a current transformer. It offers markedly low resistance, reducing power loss and temperature drift to deliver exceptional performance.

C08 series Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 10A|20A|30A|40A|50A
Output: 2.5±2V@IPN
Supply Voltage: 5V

The C08 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-50A Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 50A
Output: 2.5±2V@IPN
Supply Voltage: 5V

The C08 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-50A33 Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 50A
Output: 1.65±1.32V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-50A33U Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 50A
Output: 1.65+2.64V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-XXA33 series Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 10A|20A|30A|40A|50A
Output: 1.65±1.32V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied
orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

K02 series Open-Loop current sensor

Accuracy: 1%
Measuring Range: 50A|100A|200A|300A
Output: ±4V@IPN
Supply Voltage: ±15V

 

The K02 series is an Open-Loop current sensor based on the Hall effect. It provides an electronic measurement of DC, AC or pulse currents at the same time, and their combinations with galvanic between the primary (high current) and secondary circuits.

K03 series Open-Loop current sensor

Accuracy: 1%
Measuring Range: 100A|200A|300A|400A|500A|600A|700A|800A
Output: ±4V@IPN
Supply Voltage: ±15V

 

The K03 series is an Open-Loop current sensor based on the Hall effect. It provides electronic measurement of DC, AC or pulse currents at same time, and their combinations with galvanic between the primary (high current) and secondary circuits.

K09 series Open-Loop current sensor

Accuracy: 1%
Measuring Range: 50A|100A|200A|300A|400A|500A|600A
Output: ±4V@IPN
Supply Voltage: ±15V

 

The K09 series is an Open-Loop current sensor based on the Hall effect. It provides electronic measurement of DC, AC or pulse currents at same time, and their combinations with galvanic between the primary (high current) and secondary circuits.

K09D050D15 Open-Loop current sensor

Accuracy: 1%
Measuring Range: 50A
Output: ±4V@IPN
Supply Voltage: ±15V

 

The K09 series is an Open-Loop current sensor based on the Hall effect. It provides electronic measurement of DC, AC or pulse currents at same time, and their combinations with galvanic between the primary (high current) and secondary circuits.