C08 series Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 10A|20A|30A|40A|50A
Output: 2.5±2V@IPN
Supply Voltage: 5V

The C08 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-10A Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 10A
Output: 2.5±2V@IPN
Supply Voltage: 5V

The C08 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-10A33 Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 10A
Output: 1.65±1.32V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-10A33U Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 10A
Output: 1.65+2.64V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-20A Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 20A
Output: 2.5±2V@IPN
Supply Voltage: 5V

The C08 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-20A33 Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 20A
Output: 1.65±1.32V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-20A33U Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 20A
Output: 1.65+2.64V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-30A Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 30A
Output: 2.5±2V@IPN
Supply Voltage: 5V

The C08 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-30A33 Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 30A
Output: 1.65±1.32V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-30A33U Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 30A
Output: 1.65+2.64V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-40A Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 40A
Output: 2.5±2V@IPN
Supply Voltage: 5V

The C08 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-40A33 Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 40A
Output: 1.65±1.32V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-40A33U Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 40A
Output: 1.65+2.64V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-50A Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 50A
Output: 2.5±2V@IPN
Supply Voltage: 5V

The C08 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-50A33 Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 50A
Output: 1.65±1.32V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.

C08-50A33U Open-Loop current sensor

Accuracy: 0.5%
Measuring Range: 50A
Output: 1.65+2.64V@IPN
Supply Voltage: 3.3V

The C08-XXA33 series current sensor is a Hall-Effect sensor which is sensitive to the flux density applied orthogonally to the IC surface, and provides an analog output voltage proportional to the applied magnetic flux density. The current is sensed differentially in order to reject common-mode fields, improving accuracy in magnetically noisy environments. It is particularly adapted for high speed applications such as inverters and converters where fast response time due to fast switching is required.